Suitable forindustries such as pharmaceuticals, food, and chemicals, the concentration and evaporation intensity of the feed solution s generaly between50-60kg/m2 h. The specific gravity of the concentrate should not exceed 1.25, otherwise it will cause difficulties in discharging.
Structure
This equipment mainly consists of six components concentration tank, first condenser, vaporliquid separator, second condenser,coole, and liquid receivingtank, allmade of stainless steel The concentration tank is a jacketed structure, the condenser is a tubular type, and the cooler is a serpentine type.
Main technical parameters
| Volume L | 50 | 100 | 200 | 300 | 500 | 700 |
| Steam pressure MPa | ≤0.15 | ≤0.15 | ≤0.15 | ≤0.15 | ≤0.15 | ≤0.15 |
| Vacuum degree mmHg | ≤700 | ≤700 | ≤640 | ≤640 | ≤700 | ≤700 |
| Heating area m² | 0.4 | 0.59 | 0.8 | 1.1 | 1.45 | 1.8 |
| Condensation area m² | 1.2 | 1.7 | 2.45 | 3.0 | 3.2 | 3.6 |
| Cooling area m² | 0.25 | 0.35 | 0.4 | 0.6 | 0.7 | 0.85 |
| Receiving tank volume L | 15 | 45 | 60 | 76 | 100 | 125 |
| Net weight of equipment kg | ~350 | ~450 | ~550 | ~650 | ~800 | ~1000 |
| Dimensions (L×W×H) mm | 1200×600×2200 | 1350×750×2200 | 1700×800×2700 | 1700×1000×3400 | 2100×1200×3400 | 2400×1300×3400 |